Jun 2019 Ver. 5.4.45.0 |
---|
TS2000 series SYS PROG: version V2.280 |
TS1000 Smart series SYS PROG: version V2.280 |
TS1000 series SYS PROG: version V2.280 |
V8 series SYS PROG: version V2.280 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
TS / V8 series : PLCs newly supported. ・ OMRON E5CC/E5EC/E5AC/E5DC/E5GC supported. ・ YASKAWA DX200 (high-speed Ethernet) file control command supported. ・ Modbus slave (TCP/IP) Variable port number supported. ・ NITTOKU ITS-HRW110 connection supported. |
TS / V8 series: Calendar display in the new era name 'Reiwa' supported. V-SFT-5: 3D parts Rotation supported. V-SFT-5: 'DEL_FILE' macro command supported. |
Dec 2018 Ver. 5.4.44.0 |
---|
TS2000 series SYS PROG: version V2.270 |
TS1000 Smart series SYS PROG: version V2.270 |
TS1000 series SYS PROG: version V2.270 |
V8 series SYS PROG: version V2.270 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
TS / V8 series : PLCs newly supported. ・ MITSUBISHI ELECTRIC MR-J2S-*CL supported. ・ IDEC MICRO Smart (Ethernet TCP/IP) supported. ・ IDEC MICRO Smart connectable device added. ・ OMRON CJ2 Ethernet connection supported. ・ FUJI SPB (N mode) & FLEX-PC CPU - PLC ladder transfer function supported. |
TS / V8 series : Extended specifications ・ IDEC - D register range expanded ・ SAIA - DB register supported |
TS / V8 series: Numerals & Character display: Values appears as asterisks on a screen. V-SFT-5: Edit model selection: TS1000 Smart series added |
Aug 2017 Ver. 5.4.43.0 |
---|
TS2000 series SYS PROG: version V2.240 |
TS1000 series SYS PROG: version V2.240 |
V8 series SYS PROG: version V2.220 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 / TS2000 / TS1000 series : PLCs newly supported. ・ WAGO %MW address range extended. ・ PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported. ・ Siemens S7 PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported. ・ Hitachi HIDIC-S10(OPCN-1) supported. ・ MITSUBISHI ELECTRIC MR-J4-*A supported. ・ Fuji Electric MICREX-SX series SPF supported. ・ Yaskawa Electric DX200(High Speed Ethernet) supported. ・ High-Pressure Gas Industry R-BLT supported. |
TS series: VNC server function added. |
Feb 2017 Ver. 5.4.42.0 |
TS2000 series SYS PROG: version V2.210 |
TS1000 series SYS PROG: version V2.210 |
V8 series SYS PROG: version V2.210 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 / TS2000 / TS1000 series : PLCs newly supported. ・ OMRON NJ Series (EtherNet/IP) supported. ・ Yaskawa MP3000 Series supported. ・ KEYENCE KZ/KV series CPU supported. ・ JTEKT TOYOPUC-Nano (Ethernet) supported. ・ RKC REX-F9000 (Standard Protocol) supported. ・ Siemens S120 (Ethernet ISOTCP) supported. ・ DELTA DVP-SE (MODBUS ASCII) supported. ・ DELTA DVP-SE (MODBUS TCP/IP) supported. ・ FESTO FEC supported. |
V8 / TS2000 / TS1000 series : Function extended. ・ Modbus slave (RTU) - Broadcast function supported (station #0). ・ Modbus slave - RS422 (4-wire system) supported(Transmission mode: 2-wire/4-wire is selectable). ・ SAIA PCD Transmission mode: Data Mode/Parity Mode is selectable. |
Windows 10 (32bit/64bit) supported. |
TS2060 supported. |
Apr 2016 Ver. 5.4.41.0 |
V8 series SYS PROG: version V2.150 |
TS series SYS PROG: version V2.150 |
S806 series SYS PROG: version V2.150 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series : PLCs newly supported. ・ YASKAWA MP3000 series (Ethernet UDP/IP) supported. ・ A&D AD4402(MODBUS RTU) supported. ・ A&D AD4404(MODBUS RTU) supported. ・ FUJI FRENIC-Mini(MODBUS RTU)(C2) supported. ・ FUJI FRENIC series(CPU) supported. ・ FUJI FRENIC series(CPU) PLC Ladder transfer function added. ・ FATEK AUTOMATION FACON FB series PLC Ladder transfer function added. ・ KEYENCE KZ24/300 CPU supported. ・ Lenze Servo Drive 9400 (Ethernet TCP/IP) supported. ・ YASKAWA MP3000 series EXPANSION MEMOBUS (Ethernet) supported. ・ FUJI FRENIC-Ace (MODBUS RTU) supprted. ・ YOKOGAWA UT32A/35A (MODBUS RTU) supprted. ・ YOKOGAWA UT52A/55A (MODBUS RTU) supprted. ・ YOKOGAWA UT75A (MODBUS RTU) supprted. |
V8 series:HEX designation for bit device of Mitsubishi PLC device supported. |
V8 series:GU-01/10/11 revised hardware supported. |
Editor:Symbol import for Siemens TIA Portal supported. |
Oct 2015 Ver. 5.4.40.0 |
V8 series SYS PROG: version V2.130 |
TS series SYS PROG: version V2.130 |
S806 series SYS PROG: version V2.130 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series : PLCs newly supported. ・ MITSUBISHI FX5U/5UC series CPU supported. ・ MITSUBISHI FX5U/5UC series (Ethernet) supported. ・ MITSUBISHI FX3U/3GE series (Ethernet) supported. ・ MITSUBISHI L series CPU supported. ・ MITSUBISHI iQ-R series link supported. ・ MITSUBISHI iQ-R series (Built-in Ethernet) supported. ・ MITSUBISHI iQ-R series (Ethernet) supported. ・ OMRON V680S (Ethernet TCP/IP) supported. ・ KEYENCE KV-7000 (Ethernet TCP/IP) supported. ・ FUJI PXF (MODBUS RTU) supported. ・ FUJI FRENIC-VG1(MODBUS RTU) supported. ・ FUJI HFR-K1K supported. ・ YOKOGAWAμR10000/20000 (Ethernet TCP/IP) supported. ・ Azbil SDC15 supported. ・ Azbil SDC25/26 supported. ・ Azbil SDC45/46 supported. ・ Siemens S7-1200/1500 (Ethernet ISOTCP) supported. ・ RS Automation CSD5 (MODBUS RTU) supported. |
V8 series : The connection device specification extended. ・ FUJI ALPHA5(MODBUS RTU) : The communication setting extended. ・ WAGO 750 series : %MW address extended. ・ BECKHOFF ADS Protocol(Ethernet) : Port extended. ・ Universal serial : The communication point of the write command WM and WC extended. |
V7 series : PLCs newly supported. ・MITSUBISHI QnU series CPU supported. |
Editor: Display addresses with zero supless supported. |
Ladder transfer tool: Flow control supported. |
Feb 2015 Ver. 5.4.39.0 |
V8 series SYS PROG: version V2.090 |
TS series SYS PROG: version V2.090 |
S806 series SYS PROG: version V2.090 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8: System Program fixed. |
Jan 2015 Ver. 5.4.38.0 |
V8 series SYS PROG: version V2.080 |
TS series SYS PROG: version V2.080 |
S806 series SYS PROG: version V2.080 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
PLCs newly supported. ・ Modbus slave(ASCII) connection supported. ・ TOSHIBA VF-S15 connection supported. ・ TOSHIBA VF-MB1 connection supported. ・ TOSHIBA VF-nC3 connection supported. ・ Allen-Bradley Micro800 Controllers connection supported. ・ Allen-Bradley Micro800 Controllers(Ethernet TCP/IP) connection supported. ・ Delta DVP series Multi-link2 Ethernet connection supported. ・ Allen-Bradley Micro800 Controllers(Ethernet TCP/IP) connection supported. |
Oct 2014 Ver. 5.4.37.0 |
V8 series SYS PROG: version V2.060 |
TS series SYS PROG: version V2.060 |
S806 series SYS PROG: version V2.060 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ HYUNDAI: Hi4Robot(MODBUS RTU) ・ HYUNDAI: Hi5Robot(MODBUS RTU) |
V-SFT-5: Prohibiting screen upload supported with TS. |
TS series: Chinese simplified supported with operation log viewer. |
V8/TS series: Multi-link2 connection with V9 series supported. |
V-SFT-5: Windows 8.1 supported. |
ABB 800 xa is master and siemens plc is slave and i am trying to read data type real with modbus address 40001. Can anyone tell me that what should be start address in MBTCP read? And for word/INT with modbus address 40043? (HMI) when used with a Siemens LMV3 or LMV5 linkageless control. Use Modbus address 1, 19200 baud, 8 stop bits, 1 data bit, no parity. Installation Instructions TS Series.
Aug-1 Ver. 5.4.36.0 |
---|
V8 series SYS PROG: version V2.050 |
TS series SYS PROG: version V2.050 |
S806 series SYS PROG: version V2.050 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8: System Program fixed. |
Jul-1 Ver. 5.4.35.0 |
---|
V8 series SYS PROG: version V2.040 |
TS series SYS PROG: version V2.040 |
S806 series SYS PROG: version V2.040 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ CIMON:S series supported. ・ CIMON:S series(Ethernet) supported. ・ JTEKT:TOYOPUC-Plus supported. ・ JTEKT:TOYOPUC-Plus supported. |
V-SFT-5: Buffering area setting supported copy and paste function. |
Apr-4 Ver. 5.4.34.0 |
---|
V8 series SYS PROG: version V2.030 |
TS series SYS PROG: version V2.030 |
S806 series SYS PROG: version V2.000 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ FUJI WSZ series (Ethernet) supported. ・ ULVAC G-TRAN supported. ・ MITSUBISHI Q170MSCPU-S1 supported. ・ MITSUBISHI Q170MSCPU-S1 (Ethernet) supported. |
Jan-10 Ver. 5.4.33.0 |
---|
V8 series SYS PROG: version V2.000 |
TS series SYS PROG: version V2.000 |
S806 series SYS PROG: version V2.000 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ LS:MASTER-K series (Ethernet) supported. ・ YOKOGAWA Monitor command supported with Ethernet connection. ・ TOSHIBA nv series(Ethernet UDP/IP) ・ TOSHIBA T series/V series [T compatible](Ethernet UDP/IP) supported. ・ FUJI Micrex SX Micrex F compatible (BCD with sign) supported. |
V-SFT-5: Multi language sheet supported Vietnamese and Thai. |
Oct-31 Ver. 5.4.32.0 |
---|
V8 series SYS PROG: version V2.000 |
TS series SYS PROG: version V2.000 |
S806 series SYS PROG: version V2.000 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
PLC Ladder transfer function added:・ Simens S7-300/400 MPI |
Oct-13 Ver. 5.4.31.0 |
---|
V8 series SYS PROG: version V1.990 |
TS series SYS PROG: version V1.990 |
S806 series SYS PROG: version V1.920 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ FUJI MICREX-SX SPM/SPE supported. ・ FUJI F□JF-R series supported. ・ FUJI MICREX-SX SPH3000MM supported. ・ FUJI F-MPC04E supported. ・ MITSUBISHI L series(Built-in Ethernet)SPU device supproted. ・ UNIPULSE F805A supported. ・ SUS XA-A* supported. ・ SAMSUNG SPC series supported. ・ Panasonic FP7 supported. ・ Panasonic FP7(Ethernet) supported. |
TECHNOSHOT series: Trial period setting and upload prohibit setting added. |
TECHNOSHOT series: Smooth Font supported. |
V8 series: Alarm tracking: Acknowledge function extended. |
V8 series: Switch: Repeat speed of calculation switch improved. |
V8 series: Panasonic Network camera BB-HCM7xx series supported |
V-SFT-5: Batch Change memory: Copy & Paste from Excel sheet supported (Mitsubishi PLC only). |
V-SFT-5: Batch export/import of multi-language added. |
V-SFT-5: List of the 3D bitmap area added. |
V-SFT-5: Copy and Paste of [Multi-language] window added. |
Jun-13 Ver. 5.4.30.0 |
---|
V8 series SYS PROG: version V1.950 |
TS series SYS PROG: version V1.950 |
S806 series SYS PROG: version V1.920 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ Ultra Instruments UIC CPU(MODBUS ASCII) supported. ・ MITUBISHI Q series Multi-link2 Ethernet supported. |
May-13 Ver. 5.4.29.0 |
---|
V8 series SYS PROG: version V1.950 |
TS series SYS PROG: version V1.950 |
S806 series SYS PROG: version V1.920 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V-SFT-5:Include all the parts files as a standard part packaging. |
Apr-13 Ver. 5.4.28.0 |
---|
V8 series SYS PROG: version V1.950 |
TS series SYS PROG: version V1.950 |
S806 series SYS PROG: version V1.920 |
V7 series SYS PROG: version V1.930 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ KEYENCE KZ series supported. ・ RS Automation X8 series supported. ・ RS Automation X8 series(Ethernet) supported. ・ KOGANEI IBFL-TC supported. ・ MODBUS ASCII supported. ・ YOKOGAWA FA-M3V supported. ・ YOKOGAWA FA-M3V(Ethernet) supported. ・ YOKOGAWA FA-M3V(Ethernet ASCII) supported. ・ XINJE XC series(MODBUS RTU) supported. |
TECHNOSHOT supported. |
PLC Ladder transfer function added: ・ Simens S7-200 PPI |
V8 series: Change in Language menu on the Main Menu screen. |
V8 series:Switch to Main Menu function added. |
V-SFT-5: Windows8 32bit/64bit supported. |
V-SFT-5: USB driver auto-installation supported. |
V-SFT-5: Extended 3D parts included as standard parts files. |
Jan-13 Ver. 5.4.27.0 |
---|
V8 series SYS PROG: version V1.920 |
S806 series SYS PROG: version V1.920 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ Asahi Engineering Micro step driver D4730S supported. ・ OMRON E5CK-T supported. ・ Allen-Bradley CompactLogix L27ERM supported. ・ MITSUBISHI QnU series CPU Higher rank model supported. ・ Panasonic KW Series supported. ・ FUJI FRENIC-HVAC/AQUA(MODBUS RTU) supported. ・ OMRON PLC Multi Link2 compatible with V7 supported. |
V8 series:Trend Graph/Trend Sampling Function extended. |
V8 series:Language changeover function added to switch. |
V8 series:Siemens: Filter Import Function of DB(Data Block) supported. |
V8 series:Allen-Bradley: User Defined Tag Import Function supported. |
Nov-12 Ver. 5.4.26.0 |
---|
V8 series SYS PROG: version V1.890 |
S806 series SYS PROG: version V1.900 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
S806C: System Program fixed. |
Oct-12 Ver. 5.4.25.0 |
---|
V8 series SYS PROG: version V1.890 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ Pnasonic MINAS A4 series supported. ・ CHINO LT-400 Series supported. ・ OMRON E5AK-T supported. ・ FUJI WE1MA(Ver.B)(MODBUS RTU) supported. ・ DeviceNet supported. ・ KEYENCE KV3000 Multi-link2 with V7/V6-V8 supported. |
FUJI ELECTRIC : ・ Memory Conversion for when changing PLC model from MICREX-F to MICREX-SX supported. |
MITSUBISHI : ・ Tag Import function supported for the variable name CSV file exported by GX works2. |
V8 Series : Recipe mode Filename Sorting function supported. |
Jul-12 Ver. 5.4.24.0 |
---|
V8 series SYS PROG: version V1.830 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ Siemens TI500/505 supported. ・ Siemens TI500/505 V4 Compatible supported. ・ YAMATAKE MX series supported. ・ Allen-Bradley PLC-5(Ethernet) supported. ・ Orientalmotor High-efficiency AR Series(MODBUS RTU) supported. ・ Orientalmotor CRK Series(MODBUS RTU) supported. ・ RS OEMax NX700 Series(Ethernet) supported. ・ JTEKT TOYOPUC(Ethernet PC10Mode) supported. ・ SUNX LP-400 Supported commands extended. |
V-SFT-5:Siemens: Tag Import Function supported. |
V8 series:CC-Link Ver.2 supported. |
Banner network camera supported. |
Trend Function extended. |
Mitsubishi: Ladder Monitor Function extended. |
V810C: V609E compatible display function added. (128-color only). |
Apr-12 Ver. 5.4.23.0 |
---|
V8 series SYS PROG: version V1.790 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ MITSUBISHI A link+Net10 supported. ・ MITSUBISHI A series (OPCN-1) supported. ・ OMRON SYSMAC C(OPCN-1) supported. ・ FUJI ALPHA5 Smart(MODBUS RTU) supported. ・ FUJI FePSU Breaker supported. ・ FUJI FRENIC-MEGA SERVO(MODBUS RTU) supported. ・ Siemens S5(PG port) supported. ・ SHINKO TECHNOS ACD/ACR Series supported. ・ SHINKO TECHNOS ACS-13A supported. ・ SHINKO TECHNOS PC-900 supported. ・ SHINKO TECHNOS PCD-33A supported. ・ SHINKO TECHNOS WCL-13A supported. ・ SHINKO TECHNOS GC Series supported. ・ LS XGT/XGI series CPU supported. ・ LS XGT/XGK series (Ethernet) supported. ・ LS GLOFA GM7 CNET supported. ・ GE Fanuc 90 series (SNP) supported. ・ GE-Faunc RX3i(Ethernet TCP/IP) supported. ・ FUFENG APC Series Controller supported. |
MITSUBISHI PLC: KeepAlive supported. |
OMRON PLC: KeepAlive supported. |
V8 series: Japanese Conversion Function(FEP) extended. |
V8 series: YOKOGAWA Ladder Monitor: Device Searching Function extended. |
V8 series: YOKOGAWA Ladder Monitor: Function Block Switching extended. |
V8 series: Modbus Slave (TCP/IP): The maximum of master devices expanded to 16. |
V8 series: OMRON Ladder Monitor: CJ2 supported. |
V-SFT-5: Text Search and Replacement Function added. |
LadderComOp: Windows Vista/7 supported. |
Jan-12 Ver. 5.4.22.0 |
---|
V8 series SYS PROG: version V1.750 |
V7 series SYS PROG: version V1.920 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ OMRON E5CN-HT supported. ・ TOSHIBA MACHINE TC200 Device added. ・ VIGOR M series supported. ・ LS XGT/XGI series supported. ・ LS XGT/XGI series (Ethernet) supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP ASCII) supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP ASCII) supported. |
V808C portrait orientation supported. |
V-SFT-5: Filtering function for project view added. |
V-SFT-5: Numerical data display parts on the panel meter change function added. |
Oct-11 Ver. 5.4.21.0 |
---|
V8 series SYS PROG: version V1.720 |
V7 series SYS PROG: version V1.910 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: versionV1.940 |
V8 series: PLCs newly supported. ・ FUJI WSZ series supported. ・ MITSUBISHI Q170MCPU (multi CPU) supported. ・ MITSUBISHI Q170MCPU (multi CPU) (Ethernet) supported. ・ Siemens S7-200(Ethernet ISOTCP) supported. |
V8 series: ・ Macro command search function added ・ Panel meter functions available with 128 colors , 256 colors and monochrome type ・ E-mail port No. change function added ・ RGB (input) display compatible with V7 ・ V8 series: Windows font size in points available up to 999 |
Jul-11 Ver. 5.4.20.0 |
---|
V8 series SYS PROG: version V1.680 |
V7 series SYS PROG: version V1.910 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V7 series: System Program fixed ・Please refer to Improvement Information for further information. |
Jun-11 Ver. 5.4.19.0 |
---|
V8 series SYS PROG: version V1.680 |
V7 series SYS PROG: version V1.900 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V-SFT-5: Failure fixed |
Apr-11 Ver. 5.4.18.0 |
---|
V8 series SYS PROG: version V1.670 |
V7 series SYS PROG: version V1.890 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ YAMATAKE DMC50(COM) C Device supported. ・ DELTA TAU DATA SYSTEMS PMAC P_INT Device supported. ・ DELTA TAU DATA SYSTEMS PMAC(Ethernet TCP/IP) P_INT Device supported. ・ YOKOGAWA FA-M3 SW/SL Extended Command supported. ・ YOKOGAWA FA-M3R SW/SL Extended Command supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP) SW/SL/F Extended Command supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP) SW/SL/F Extended Command supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet UDP/IP) System-log read command supported. ・ YOKOGAWA FA-M3/FA-M3R(Ethernet TCP/IP) System-log read command supported. ・ YOKOGAWA FA-M3/FA-M3R the defult setting of Communication parameter changed. ・ Universal Serial from PLC1 to PLC8 supported. ・ Jetter JetControl Series2/3(Ethernet UDP/IP) supported. ・ TOHO TTM-000 supported. ・ Allen-Bradley NET-ENI(SLC500 Ethernet TCP/IP) supported. ・ Allen-Bradley NET-ENI(Micrologix Ethernet TCP/IP) supported. ・ Fuji Electric FALDIC-W series supported. ・ GE Fanuc 90 Series(SNP-X) Multi Link2 compatible with V7 supported. ・ SHARP JW300 series supported. ・ SHARP JW series(Ethernet) supported. ・ SHARP JW311/213/321/322(Ethernet) supported. ・ SHARP JW331/332/341/342/352/362(Ethernet) supported. ・ Fuji Electric MicrexSX Redundancy supported. ・ KOYO SR-T(K Protocol) supported. ・ KOYO SU/SG supported. ・ GE Fanuc 90 series supported. |
V7 series: PLCs newly supported. ・ Fuji Electric MicrexSX T-Link Redundancy supported. |
PLC Ladder transfer function added: ・ MITSUBISHI QnA LadderMonitor supported |
V8 series: ・ Range after scaling numbers in Number Display reflected to Minimum and Maximum numbers. ・ The function of printing Data Sheet extended. |
V-SFT-5: ・ The dialogue setting of MES reformed. ・ The order INC of the Entry Target possible to be changed by Batch Change. ・ Windows Vista/Windows 7 64bit supported. ・ The addition of Attribute Specification Memory in Detail Tab of Number Display. ・ The brightness adjusting Macro/ BRIGHT/ for V808CH supported. ・ Tags of importing of Siemes S7-200 Format supported. |
Feb-11 Ver. 5.4.17.0 |
---|
V8 series SYS PROG: version V1.650 |
V7 series SYS PROG: version V1.880 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ YAMATAKE NX(CPL) ・ YAMATAKE NX(Modbus RTU) ・ YAMATAKE NX(Modbus TCP/IP) ・ Agilent 4263 series ・ Turck BL Series Distributed I/O (MODBUS TCP/IP) ・ RKC FB100/FB400/FB900 (MODBUS RTU) ・ MOELLER PS4 ・ FUJI FRENIC5000G11S/P11S ・ FUJI PH series ・ Allen-Bradley ControlLogix(Ethernet) CPU slot No. supported. |
V8 series: Grobal Overlap supported. |
V8 series: Additional features for a panel meter supported. |
V8 series: Mute setting for Overlap buzzer supported. |
V8 series: UPDATE function added to MES macro command. |
V8 series: Backup making feature for Recipe function supported. |
V8 series: Archive error log for wiring to external media supported. |
V-SFT-5: ・ Marging feature for the message supported. ・ The limit of the number of the letters in a switch/lamp changed. |
Nov-10 Ver.5.4.16.0 |
---|
V8 series SYS PROG: version V1.610 |
V7 series SYS PROG: version V1.870 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V-SFT-5: Failure fixed |
Oct-10 Ver.5.4.15.0 |
---|
V8 series SYS PROG: version V1.610 |
V7 series SYS PROG: version V1.870 |
V6 series SYS PROG: version V1.930 |
V606e series SYS PROG: version V1.940 |
V8 series: PLCs newly supported. ・ SANMEI CutyAxis ・ OMRON SYSMAC CS1/CJ1 DNA ・ OMRON SYSMAC CS1/CJ1 DNA(Ethernet) ・ Siemens S7-1200(Ethernet ISOTCP) ・ CIMON BP series ・ CIMON CP series ・ CHINO LT230(MODBUS RTU) ・ CHINO LT300(MODBUS RTU) ・ CHINO LT830(MODBUS RTU) ・ CHINO DB1000B(MODBUS RTU) ・ CHINO KR2000(MODBUS RTU) ・ Bosch Rexroth IndraDrive |
V7 series: PLCs newly supported. ・ Siemens S7-1200(Ethernet ISOTCP) ・ MITUBISHI QnU built-in Ethernet |
V8 series: Continuous printing of data sheet printing supported. |
V8 series: Float numbers supported for trend graph / trend sampling and data sampling. |
V8 series: Add and delete for numbers supported for numeral entry. |
V8 series: Offset memory supported for numeral data display and character display. |
V-SFT-5: ・ Remapping of the destination screen number supported for the switch function [screen]. ・ End memory designation and memory count designation supported for Memory batch change. |
Jul-10 Ver.5.4.14.0 |
---|
V8 series SYS PROG: version V1.570 |
V7 series SYS PROG: version V1.860 |
V6 series SYS PROG: version V1.930 |
V8 series: PLCs newly supported. ・ WAGO 750series(MODBUS RTU) ・ WAGO 750series(MODBUS Ethernet) ・ UNITORONICS Vision Series(ASCII Ethernet TCP/IP) ・ HITACHI HIDIC-S10α ・ MITSUBISHI QnU series(Built-in Ethernet) ・ MITSUBISHI L series link ・ MITSUBISHI L series (Built-in Ethernet) |
V8 series: Remote Desktop: Auto reduction function enhanced. |
V8 series: Operation Log: Filtered display of the log viewer added. |
V8 series: Operation Log: Operation log can be selected with each switch. |
V8 series: Yokogawa: Comment can be uploaded when using ladder monitor feature. |
V8 series: Mitsubishi: Compatible memory device extended with Q series. |
V8 series: Macro command: IF(TST) macro command added. |
V8 series: Macro command: GRE_TO_CLND command added (converting date). |
V8 series: Graphs: Float data supported. |
V8 series: Total number to be registered is extended with Overlap Library/Screen Library/Page Block |
Jun-10 Ver.5.4.13.0 |
---|
V8 series SYS PROG: version V1.560 |
V7 series SYS PROG: version V1.850 |
V6 series SYS PROG: version V1.930 |
V8 series: System Program fixed ・ - The system program will be upgraded to Ver.1.560 due to the change of the flash memory which is used in V8 series. |
Apr-10 Ver.5.4.12.0 |
---|
V8 series SYS PROG: version V1.530 |
V7 series SYS PROG: version V1.850 |
V6 series SYS PROG: version V1.930 |
V7 series: System Program fixed. ・ Please refer to Improvement Information for further information. |
Apr-10 Ver.5.4.11.0 |
---|
V8 series SYS PROG: version V1.530 |
V7 series SYS PROG: version V1.840 |
V6 series SYS PROG: version V1.930 |
V8 series PLCs newly supported. ・ FUJI FVR-E11S ・ M-SYSTEM R1M series(MODBUS RTU) ・ OMRON KM20-B40 ・ OMRON KM100 |
V8 series: Panasonic network camera supported. |
V8 series: Japanese Conversion Function - supported models extended. |
V8 series:OMRON SYSMAC CS1/CJ1 USB/Ethernet ladder transfer function |
V8 series: MODBUS RTU EXP Free Format ・ maximum settable table number extended. |
V8 series: Return switch - returning to the screen changed externally supported. |
V8 series: PLC ladder monitor - supported function extended. |
V8 series: PLC ladder monitor ・ OMRON CJ1 supported. |
V8 series: Multi-link2 compatibility with V7 supported. |
V-SFT-5: Windows 7 supported. |
V-SFT-5: Font size became changeable in Macro edit screen. |
V-SFT-5: Comments in multiple lines supported in Macro edit screen |
V-SFT-5: File name added to the title in Macro edit screen |
V-SFT-5: Selection Environment Setting - Option to apply to all screens supported. |
V-SFT-5: Option for auto-update of System Program (SYS PRG) supported. |
Frame Auto Fit - right-click menu added to support the batch change of multiple parts. |
V-SFT-5: Tag - usage list function supported. |
Feb-10 Ver.5.4.10.0 |
---|
V8 series SYS PROG: version 1.520 |
V7 series SYS PROG: version 1.830 |
V6 series SYS PROG: version 1.930 |
V8 series PLCs newly supported. ・ GLOFA CNET ・ GLOFA GM series CPU ・ Allen-Bradley PLC-5 ・ MITSUBISHI MR-J2S-*A ・ SHARP DS-30D ・ SHARP DS-32D ・ YASKAWA MP2000 ・ YASKAWA MP2000 series (Ethernet) |
Trend Graph: Background drawing feature supported. |
V-SFT-5: Import/export feature in Tag Database supported. |
V-SFT-5: Memory/number remapping when moving screens supported. |
V-SFT-5: Batch change of Screen Library supported. |
V-SFT-5: Extended cross-reference feature supported. |
V-SFT-5: export/import of Network Table supported |
Nov-09 Ver.5.4.9.0 |
---|
V8 series SYS PROG: version 1.500 |
V7 series SYS PROG: version 1.820 |
V6 series SYS PROG: version 1.930 |
V8 series PLCs newly supported. ・ Automationdirect DirectLOGIC(Ethernet UDP/IP) ・ IDEC MICRO Smart pentra ・ TOSHIBA MACHINE VELCONIC series ・ MODBUS RTU EXP Format |
Oct-09 Ver.5.4.8.0 |
---|
V8 series SYS PROG: version 1.460 |
V7 series SYS PROG: version 1.800 |
V6 series SYS PROG: version 1.910 |
V8 series: MITSUBISHI ladder monitor extensions. |
V8 series: YOKOGAWA USB/Ethernet ladder transfer function supported. |
V8 series: Symbol edit function supported. |
V8 series PLCs newly supported. ・ CHINO DP1000G ・ IAI RCP2/ERC ・ IAI RCS/E-CON ・ FUJI ELECTRIC MicrexSX(SPH) Batch activation/stop supported. ・ FUJI ELECTRIC FRENIC-MEGA(MODBUS RTU) Broadcast writing supported. ・ FUJI ELECTRIC FRENIC-5000VG7S(MODBUS RTU) Broadcast writing supported. ・ FUJI ELECTRIC FRENIC-Multi(MODBUS RTU) Broadcast writing supported. ・ FUJI ELECTRIC FRENIC-Eco(MODBUS RTU) Broadcast writing supported. ・ FUJI ELECTRIC PXG(MODBUS RTU) Port number is extended up to no. 247. ・ FUJI ELECTRIC PXH(MODBUS RTU) Port number is extended up to no. 247. ・ FUJI ELECTRIC PHR(MODBUS RTU) Port number is extended up to no. 247. |
V-SFT-5: Macro symbol can be appeared on switch. |
V8 series: 2-port supported with touchswitch emulation. |
V8 series: Logout function supported in macro. |
V8 series: Network camera AXIS M1011 supported. |
V8 series: V7 compatible display in PAL supported. |
Aug-09 Ver.5.4.7.0 |
---|
V8 series SYS PROG: version 1.460 |
V7 series SYS PROG: version 1.800 |
V6 series SYS PROG: version 1.910 |
V8 series PLCs newly supported. ・ MODICON ModbusRTU ・ MITUBISHI MR-J3-*T ・ SHIMADEN Shimaden Standard Protocol ・ MODBUS RTU 1:n Multi-link2(Ethernet) supported. ・ Telemecanique TSX Micro ・ SHINKO TECHNOS JCx-300 series ・ LS GLOFA GM series (Ethernet UDP/IP) |
V8 series: RKC Setting range of the station number was extended |
Jul-09 Ver.5.4.6.0 |
---|
New model ・ S808 series is added. |
V8/V7/V6 series PLCs newly supported. ・ MITUBISHI FX3 series (A Protocol) supported. |
V8 series PLCs newly supported. ・ MITUBISHI A series (CC-Link) supported. ・ MITUBISHI QnA series (CC-Link) supported. ・ GE Fanuc 90 series(Ethernet TCP/IP) supported. ・ DELTA DVP series supported. |
V8 series: Allen-Bradley: BOOL is supported forControl Logix/Compact Logix |
V8 series: Modbus RTU: Data length of 7-bit is added. |
V8 series:Continuous buzzer for switch supported. |
V-SFT-5: Macro tool bar added. |
V-SFT-5: Batch setting of the Page block edit is supported. |
May-09 Ver.5.4.4.0 |
---|
V8series PLCs newly supported. ・ MITSUBISHI FX3U-ENET supported. ・ UNIPULSE F720A supported. ・ UNIPULSE F800 supported. ・ EMERSON EC10/20/20H (MODBUS RTU) supported. |
Apr-09 Ver.5.4.3.0 |
---|
V8 sereis: AB: Memory range extended from 65:255 to 255:255 |
Fuji: SX Instrumentation Package function supported. |
V808C: V609E compatible display function added. (128-color only) |
V8series PLCs newly supported. ・ Hitachi Industrial Equipment System SJ300series supported. ・ Hitachi Industrial Equipment System SJ700series supported. ・ UNIPULSE F340A supported. ・ UNIPULSE F371 supported. ・ TOSHIBA EXseries supported. ・ Banner Vision Ethernet I/P Protcol supported. ・ MITSUBISHI QnH(Q)series (Ethernet ASCII) supported. ・ MITSUBISHI QnH(Q)series (Multhi CPU) (Ethernet ASCII) supported. ・ Siemens S7-200PPI: 187.5kbps supported. |
V7/V6series PLCs newly supported. ・ KEYENCE KV-3000/5000 supported. |
Feb-09 Ver.5.4.1.0 |
---|
V8 sereis: Remote Desktop function supported. |
V8series PLCs newly supported. ・ FL-Net supported. |
home | products | how to buy | support & downloads | literature | search |
Up to 31 AC10 drives can be connected to a Version 2 TS8000 HMI with Modbus RTU via RS485.
Equipment needed:This will require an AC10 drive, a TS8000 HMI and the DSI8000 (or DSI3 software) a USB cable, and a 124 ohm resistor.
There is a pre-configured TS8008 configuration example which corresponds to this application labeled 3855_TS8000_to_AC10_Modbus_8_inch.dsi. It is configured for 2, AC10 Drives communicating to a TS8008 HMI 8 inch screen.
NOTE: AC10 RS485 MODBUS communications to Version 1 TS8000 HMI is intermittent. It is recommended to use only Version 2 TS8000s.
Procedure
Wire the AC10 to the TS8000.
For RS485 2 wire connection, use an RJ45 connector from the RS485 terminal on the TS8000.
Pins 1 or 7 connect to the A terminal on the AC10 and terminals 2 or 8 connect to the B terminals on the AC10.
Pins 1 or 7 connect to the A terminal on the AC10 and terminals 2 or 8 connect to the B terminals on the AC10.
Note: It is required to have a 124 ohm resistor across the A and B terminals of the last drive in the network. Terminals A&B on the AC10 are swapped per the cables markings. Thus the drawing is correct.
Configure the AC10 Communication Parameters
Example Settings:
F900 (inverter address): 13 for Drive1 and 14 for Drive2.
F901 (Modbus mode selection): 2 (RTU mode)
F902 (Stop Bits): 1
F903 (Parity Check): 1 (Odd)
F904 (Baud Rate): 6 (57600)
F900 (inverter address): 13 for Drive1 and 14 for Drive2.
F901 (Modbus mode selection): 2 (RTU mode)
F902 (Stop Bits): 1
F903 (Parity Check): 1 (Odd)
F904 (Baud Rate): 6 (57600)
Also:
F200 Source of Start Command = 3: Modbus or 4: Keypad + Terminal + Modbus
F201 Source of Stop Command = 3: Modbus or 4: Keypad + Terminal + Modbus
F203 Main Frequency Source = 10: Modbus
F200 Source of Start Command = 3: Modbus or 4: Keypad + Terminal + Modbus
F201 Source of Stop Command = 3: Modbus or 4: Keypad + Terminal + Modbus
F203 Main Frequency Source = 10: Modbus
Configure the TS8000
Open DSI8000 or DSI3 and select the Communications window. This example was done with DSI. Select the RS485 port by clicking on the icon in the left hand pane. Then click 'Edit' in the top right-hand of the screen and select 'Modbus Master'.
Set the Baud Rate and Parity to match the settings in the drive.
Click on PLC1. Select the Drop Number box and enter the inverter address which matches the setting in parameter F900.
IMPORTANT: Click the Extended tab and select the ping holding register text box. The number in here must match a 'parameter address' in the drive. Set the number in here to 262. This corresponds to parameter F105 Software Version 'parameter address' location (The 262 comes from converting 105 (hex) to 261 +1).
AC10 Parameter Access via the TS8000
The parameters in the AC10 have to be converted into numbers that can be used in the Modbus registers.
Example: F111 (Max Frequency) the parameter number consists of 2 bytes.
01 + 11 Convert these into hexadecimal form to get 01 0B.
Convert this back to decimal and add 1. So 10B(h) = 267 + 1 = 268.
So the Modbus register = 400000 + 268 = 400268.
Set up the TS8000 Data Tags
Close the Communications window and double click on the Data Tags icon. Click on the data tags icon and create integer tags as shown. Name one as Speed and the other as Command. The speed tag will relate to the Target Frequency parameter F113.
F113 = 010Dh = 269 + 1 = 270.
Command is tag is F2000 = 8192 + 1 = 8193.
Set up the 'User Interface'
Double click on the User Interface icon. Once the tags are created you can create an integer text box and configure it to enter the speed. The AC10 refers to the Speed in Hertz rather than a percentage as most other Parker drives do.
The value of the command tag sets the drive mode.
Run Forward = 0001
Run Reverse = 0002
Ramp Stop = 0003
Coast Stop = 0004
Run Forward = 0001
Run Reverse = 0002
Ramp Stop = 0003
Coast Stop = 0004
Create A button for each mode and set the integer value to match the function of the button.
If you are connected to the AC10 you can download it into the drive by pressing F9.
You should now be able to run the drive in both directions and Stop it with either a Ramped Stop or a Coast Stop. More parameters are listed in the AC10 product manual HA502320U001.
You should now be able to run the drive in both directions and Stop it with either a Ramped Stop or a Coast Stop. More parameters are listed in the AC10 product manual HA502320U001.
Note: If the AC10 drive is 'Faulted' communication to the TS8000 will be lost and dash lines will appear for the data values.
16NOV2016 LS